Thermal cut-out AC02

Thermal cut-out AC02

8.26

Previous lowest price was 10.16.

SKU: N/A Category:

Description

Catalog Card AC02 PDF

Collective pack of 100 pcs

Contact
SPST n.c.
Rated Voltage
250V; AC; DC
Rated current
of resistance loading lzn, cosinus phi =1
6,3 A
of resistance and induction loading, cosinus phi=0.6
4,0 A
Operating life at rated load
10000 cycles
maximum load/operation life10 A/2000 cycles
Rated operating temperature range
65°C – 180°C
Operating temperature tolerance
±5K/±10K
Hysteresis zone
30 ± 15 K
Rate of temperature change to determine operating temperature
0,5 ÷ 1 K / min
Thermal resistance
max 190°C/ 1 min
Degree of protection (acc. to EN-60730-1)
IP 00
PTI index of insulation materials used
250 V
Designn.c non-electronic
Electrical strength of insulation
2500 V; 50 Hz
Transition resistance (without leads)
max < 25 mili ohm
Standard cable lengths60mm
VDE
UL
YFZW8.E178326

Additional information

Temperatura

100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95