Thermal cut-out AKW33

Thermal cut-out AKW33

30.68

Previous lowest price was 37.74.

SKU: N/A Category:

Description

Catalog Card AKW33 PDF

Collective pack of 100 pcs

Contact
DPST n.c.
Rated Voltage
400V; AC; DC
Rated current
of resistance loading lzn, cosinus phi =1
32 A
of resistance and induction loading, cosinus phi=0.6
10 A
Operating life at rated load
300 cycles
maximum load/operation life
42 A/30 cycles
Rated operating temperature range
65°C – 150°C
Operating temperature tolerance
±5K/±10K
Hysteresis zone
manual reset
Rate of temperature change to determine operating temperature
0,5 ÷ 1 K / min
Thermal resistance
max 210°C/ 1 min
Degree of protection (acc. to EN-60730-1)
IP 00
PTI index of insulation materials used
250 V
Designn.c non-electronic
Electrical strength of insulation
4000 V; 50 Hz
Transition resistance (without leads)
max < 40 mili ohm
VDE
 

 

UL
BEAB
logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.