Thermal cut-out AM06
zł8.26
Previous lowest price was zł10.16.
Description
Catalog Card AM06 PDF
Collective pack of 100 pcs
Contact | SPST n.c. |
Rated Voltage | 250V; AC |
Rated current | |
of resistance loading lzn, cosinus phi =1 | 2,5 A |
of resistance and induction loading, cosinus phi=0.6 | 1,6 A |
Operating life at rated load | 10000 cykli |
maximum load/operation life | 3,6 A/2000 cykli |
Rated operating temperature range | 65°C – 160°C |
Operating temperature tolerance | ±5K/±10K |
Hysteresis zone | 30 ± 15 K |
Rate of temperature change to determine operating temperature | 0,5 ÷ 1 K / min |
Thermal resistance | max 210°C/ 1 min |
Degree of protection (acc. to EN-60730-1) | IP 54 |
PTI index of insulation materials used | 250 V |
Design | n.c nie elektroniczna |
Electrical strength of insulation | 2500 V; 50 Hz |
Transition resistance (without leads) | max < 40 mili ohm |
Standard cable lengths | 60mm |
VDE | |
UL | |
BEAB |