Thermal cut-out AM07

Thermal cut-out AM07

9.44

Previous lowest price was 11.61.

SKU: N/A Category:

Description

Karta Katalogowa AM07 PDF

Collective pack of 100 pcs

Contact
SPST n.c.
Rated Voltage
250V; AC
Rated current
of resistance loading lzn, cosinus phi =1
2,5 A
of resistance and induction loading, cosinus phi=0.6
1,6 A
Operating life at rated load
10000  cykli
maximum load/operation life
3,6 A/2000  cykli
Rated operating temperature range
65°C – 160°C
Operating temperature tolerance
±5K/±10K
Hysteresis zone
30 ± 15 K
Rate of temperature change to determine operating temperature
0,5 ÷ 1 K / min
Odporność termiczna 
max 210°C/ 1 min
Degree of protection (acc. to EN-60730-1)
IP 68
PTI index of insulation materials used
250 V 48DC
Designn.c non-electronic
Electrical strength of insulation
2500 V; 50 Hz
Transition resistance (without leads)
max < 40 mili ohm
Standard cable lengths60mm
VDE
UL
BEAB

 

Additional information

Temperatura

100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 65, 70, 75, 80, 85, 90, 95